Calculate the required pump horsepower based on flow rate and total dynamic head. Size your pump correctly for optimal efficiency.
Enter your desired flow rate and pool type to find the right pump size.
GPM needed for adequate turnover. Typical: 40-80 GPM.
Determines the total dynamic head (TDH) used in the calculation.
0
horsepower
-
-
-
-
Select a pump with horsepower equal to or slightly above the calculated requirement.
Properly sizing your pool pump is essential for efficient operation. An undersized pump won't provide adequate circulation, while an oversized pump wastes energy and can damage equipment. This calculator uses hydraulic engineering formulas to determine the right horsepower for your system.
Pool pump sizing involves several types of horsepower measurements:
The theoretical power needed to move water at the required flow rate against the system head. Calculated as:
WHP = (GPM × Head in feet) ÷ 3,960
The actual power the pump impeller needs, accounting for pump efficiency:
BHP = WHP ÷ Pump Efficiency
The calculator assumes typical efficiencies of 70% for the pump and 85% for the motor. Small pool pumps are often less efficient, so check your pump's curve and nameplate before choosing a size.
A motor's HP rating is its shaft output, so the motor must be rated for at least the brake horsepower. Motor efficiency affects the electricity it draws, not the rating:
Motor HP ≥ BHP; Input Watts = BHP × 746 ÷ Motor Efficiency
Total Dynamic Head is the total resistance the pump must overcome, measured in feet of water:
It depends on your pool volume (for flow rate) and plumbing system (for head). A typical 20,000-gallon pool turned over in 8 hours needs about 42 GPM. With standard in-ground plumbing (about 35 ft of head) that works out to roughly 0.5 brake horsepower, so a 1/2 to 3/4 HP pump is enough; heaters, long runs, and water features raise the head and the size. Use the calculator above for your specific situation.
No. Oversized pumps waste energy, can create excessive pressure that damages equipment, and may cause water to bypass the filter. Proper sizing is more important than maximum power.
Variable-speed pumps can run at lower speeds for routine filtration and ramp up when needed. Size them for maximum flow requirements, but they'll typically run at much lower (and more efficient) speeds.
Measure static lift, calculate friction loss from pipe length and fittings, and add equipment pressure drops. Alternatively, use typical values for your pool type as a starting estimate.