Raypak

Digital Low NOx ASME 207A-407A

Gas Heater

Manual-backed spec and service reference for Raypak Digital Low NOx ASME pool heaters, models 207A, 267A, 337A, and 407A.

Raypak Digital Low NOx ASME 207A-407A
199,500 - 399,000 BTU/hr
BTU Range
Natural Gas
Gas Type
120/240 VAC
Voltage
100 GPM
Max Flow
20 GPM
Min Flow

Specifications

Heating
BTU Range199,500 - 399,000 BTU/hr
Gas TypeNatural Gas
Gas Inlet Connection3/4 in. NPT
Electrical
Voltage120/240 VAC
PhaseSingle phase
Frequency60 Hz
Performance
Min Flow (GPM)20 GPM
Max Flow (GPM)100 GPM
Temperature Range32-175 F
Certifications
CSA CertifiedYes

Pros & Cons

Pros

  • ASME Low NOx variant with manual-backed diagnostics and service menu.
  • Manual includes status/fault messages, control logic, troubleshooting, wiring, and parts.
  • Covers 207A, 267A, 337A, and 407A models.

Watchouts

  • Confirm ASME and Low NOx configuration before using parts from non-ASME Digital heaters.
  • Some limits and switches are manual reset on ASME units.
  • Combustion and gas service should be handled by qualified technicians.

Error Codes & Troubleshooting

Sensor Failure / Sensor Open / Sensor Short
Temperature sensor out of range. Inspect thermistor, wires, and connector at Terminal P1. Check resistance against chart values. Replace thermistor if not within 10%; if okay, replace the circuit board.
Water Sw Open
Water flow or pressure switch issue. Verify water flow and pressure, and clean the filter/strainer before replacing the switch.
Hi Limit 1 Fault / Hi Limit 2 Fault
High limit switch open. Verify water flow and inspect the internal thermostat and bypass valve. ASME units are manual-reset — press MODE to reset.
Ignition Lockout
Pilot flame not established, or lost during trial for main burner. Check power at the pilot valve, check for spark, and verify pilot orifice and igniter clearance.
Ignition Failure
Gas supply or valve operation issue. Verify gas is reaching the heater and confirm valve operation.

Replacement Parts

PartPart NumberDescription
105°F U.G. Service Kit (206-207, 266-268)018759FManual-recommended kit for harmonics/whining noise after basic checks (debris, restriction, low flow/scale) don't resolve it.
105°F U.G. Service Kit (336-337, 406-408)018758FManual-recommended kit for harmonics/whining noise after basic checks (debris, restriction, low flow/scale) don't resolve it.

Related Models

Related Articles

Track This Equipment on Customer Accounts

Log equipment details, service history, and warranty info for every customer with PoolDial.