CMP

DEL UV-C 50

UV-C Sanitizer

CMP DEL UV-C 50 supplemental sanitizer with two 254 nm UV lamps, 120/240V power support, and a 100 GPM manual-listed maximum flow rate.

CMP DEL UV-C 50
120/240 VAC
Voltage
100 GPM
Max Flow

Specifications

Electrical
Voltage120/240 VAC
Frequency50/60 Hz
Current Draw0.8A at 120V / 0.4A at 240V
Max Watts96W
Performance
Max Flow (GPM)100 GPM
Physical
WeightApprox. 28 lb shipping weight
Temperature Range35F to 104F ambient
Plumbing ConnectionInstall in the pool main return line after the filter, preferably before the heater and chlorine feeder or chlorine generator.
Flow SwitchFlow Switch Kit EUV-FS-01 required if installed below water level.

Pros & Cons

Pros

  • Manual gives electrical values, shipping weight, ambient temperature, and 100 GPM max flow.
  • Uses two germicidal UV lamps tuned to 254 nm.
  • Manual provides specific troubleshooting checks for indicator and UV lamp failures.

Watchouts

  • Supplemental sanitizer only; the manual still recommends maintaining a 1-3 ppm free chlorine residual.
  • Below-water-level installations require the EUV-FS-01 flow switch kit.
  • UV lamps are mercury-containing service items with an 18-month replacement interval.

Error Codes & Troubleshooting

Green Indicator Not Lit
Manual troubleshooting starts with no power from the source, breaker checks, loose wiring, wiring breaks, or a burned-out indicator light.
One Or Both UV Lamps Not Lit
Manual troubleshooting lists lamp connector seating, water fouling at lamp connections, bad UV lamp, and bad ballast.

Open full interactive troubleshooter →

Replacement Parts

PartPart NumberDescription
Quartz Tube Assembly9-1416-01Manual service list says to clean every 6 months and replace as needed.
UV Lamp9-1421-01Manual service list says to replace UV lamps every 18 months.

Related Models

Related Articles

Track This Equipment on Customer Accounts